Sending RS232 Commands Via UDP
38 Planar UltraLux Series Installation Guide
Sending RS232 Commands Via UDP
The UDP port 57 accepts the same command sets as RS232. It is convenient for IP
control applications and can be tested with a UDP terminal program such as the
Hercules SETUP utility available from www.HW-group.com
Note: Ensure that the Enable ASCII command service (UDP port 57) box is checked on the
Access Control page of the Remote Monitoring software.
Notice the following in the example below:
The Module IP address must match the Planar device servers IP address
•Enter 57 in the Port box.
“04 21 16 C5” in the Send box corresponds to the Get Power Status RS232
command.